The steel building is the default structure across Saskatchewan: farm shops, potash and industrial support buildings, equipment storage, grain handling, and most of the commercial construction in smaller centres. It is also the hardest common building to insulate well, for reasons that have nothing to do with how much insulation gets specified. Metal building spray foam insulation in Saskatchewan is mostly a condensation and continuity problem.
Steel conducts, and that is the whole issue
A steel purlin or girt is a direct thermal path from inside to outside. Where insulation is compressed against it or stops short of it, that line of steel sits close to outside temperature while the air inside the building is warmer and carries moisture. The result is condensation on the steel, running down the inside of the wall, in a building the owner was told was insulated.
The same applies at every fastener. A long wall has a regular grid of them, each one a small thermal bridge, and in a prairie winter the temperature difference across the assembly is large enough for that to matter.
Why sealing matters more than thickness in a steel building
- The fastener grid - hundreds of small thermal bridges in a regular pattern down a long wall.
- Purlin and girt lines - continuous steel running the length of the building, and the usual condensation surface.
- Panel laps and side laps - the seams a sheet-metal building is assembled from, every one of them an air path under wind pressure.
- Overhead door surrounds - the largest opening, framed in steel, carrying the most movement.
- Base plate and eave lines - long horizontal seams at the top and bottom of the wall.
A continuous sprayed layer that adheres to the inside face addresses the bridge and the seam at the same time, which is why this building type is where the method differs most from batt and vapour barrier.
The intermittent heating problem is sharper in steel
Many of these buildings are heated to work in and then allowed to go cold. Steel changes temperature quickly, so a metal building swings further and faster than a wood-framed one. Each swing is a chance for warm moist interior air to reach a cold steel surface. This is the specific reason a farm shop can feel damp and show rust on fasteners while nominally carrying insulation.
Wind on a long steel wall
Prairie exposure and long walls combine badly. A pressure difference across a wall assembled from overlapping panels pushes air through the laps, and that air carries the moisture that then condenses on the steel behind. The air-seal and the condensation problem are the same problem viewed from two sides, which is why they are best solved in one pass rather than two.
Metal Building Spray Foam Insulation Saskatchewan: Common Questions
Why does my insulated steel shop still drip? Almost always because the steel is bridging. If insulation is compressed at the purlins or stops short of them, those lines stay cold and the moisture in the building's air condenses on them.
Is this a Saskatchewan problem or a steel problem? Both. Steel conducts anywhere, but the temperature difference across the assembly in a Saskatchewan winter is large, and the wind exposure drives the moist air to the cold surface.
Does the fastener grid really matter? On a long wall there are a great many fasteners and they are regularly spaced. Individually small, collectively a measurable path, and visible as rust streaks where condensation has been running.
Should the building be heated continuously instead? That is an operating decision, not an envelope one, and it is usually not practical on a farm or in equipment storage. The envelope answer is continuity, so the assembly tolerates the cycling.
Status of this division
Spray Foam Insulation Saskatchewan is a reserved name and the division is not operating yet. This page explains how steel buildings behave in this climate. It makes no claim about who would do the work, what they hold, where they cover or what it would cost.